Part Number Hot Search : 
M93C46 SA33A 2309NZ MEGA3 AA3528EC CUPPB 2SC539 10X10
Product Description
Full Text Search
 

To Download TD4PX Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  page 1 of 3 www.aecsensors.com sales department tel: (888) 847-6552 TD4PX series electronic roll-over switch specifcations output pnp (see fig. 3 for details) output load dc 0.5a (max.) short circuit protection yes supply voltage dc 8 - 30v current consumption 25ma polarity protection yes boot up time <10ms housing plastic injection moulded (pbtp) dimensions (approx.) l x w x h 40 x 40 x 25mm mounting m3 screws connection m12 5 pin male connector (others to special order) weight approx. 50g ambient temperature -25c to +85c (storage and operating) humidity 0 - 95% non-condensing sealing iec60529 ip67 shock resistance max. 10g measuring range detection angle 40 standard, other angles can be specifed - see ordering code centering function pre-centered at 0, range 5 frequency response (-3db) 0 - 0.1hz accuracy 5 offset error 0 (after factory zeroing) resolution 0.09 temperature coeffcient 0.04/k ? roll-over detection and fuel cut-off ? wide trigger angle with 2 hysteresis ? 3 sec delay on trigger and reset angle standard ? non resettable - one shot optional ? optional reset by external module or auto reset after 90s ? up to 1a output to drive up to 2 x mini-iso relays ? optional led for trip status indication rohs compliant ref: TD4PX series 011916jhm specifcations are subject to change without notice. e&oe.
all dimensions in millimeters. not to scale. page 2 of 3 www.aecsensors.com sales department tel: (888) 847-6552 TD4PX series electronic roll-over switch ref: TD4PX series 011916jhm dimensions and mounting holes fig. 1 1 2 3 4 5 m12 5p male connector pin 1: +supply voltage pin 2: reset function (pin ftted but not connected for non-resettable version) pin 3: gnd (0v) pin 4: output pin 5: factory use (centering/zero set) - leave unconnected. ordering codes t d 4 p x - 0 4 0 - d s m - p n p - p * * * * * series type p***** = reserved for custom / specifc versions trigger angle (in 1 steps) (040 = 40 ) p00001= non-resettable, with led status indicator, 1 second delay d = 10 - 30vdc p00002 = externally resetta - ble 1 with led status indicator, 1 second delay s = standard accuracy p00003 = auto reset after 90s delay, with led status indica - tor, 1 second delay m = medium accuracy h = high accuracy x = extra high accuracy pnp output to drive up to 2 x mini-iso automotive relays terminations leave empty for 2000mm pur cable empty cable length in mm if not 2000mm m = m12 male connector (pins) f = f12 female connector (socket) 1 external reset requires an optional external confgurator box optional led position specifcations are subject to change without notice. e&oe.
mounting orientation fig. 2 TD4PX series electronic roll-over switch american electronic components inc., 1101 lafayette st. elkhart, in46516 page 3 of 3 www.aecsensors.com sales department tel: (888) 847-6552 specifcations are subject to change without notice. e&oe. ref: TD4PX series 011916jhm the default 0 position is when the switch is mounted horizontally and no acceleration (or tilt) is applied. when mounting, please ensure suffcient space is left to allow for the cable (not supplied) and connector . undue stress on the cable and connector should be avoided. output function fig. 3 0 - 40+ 40 v 0 safe are a unsaf e area unsaf e area pnp out ( vs upply) (with e xt ernal pull- down resistor ) the pnp output is designed to drive up to 2 standard 12vdc mini-iso automotive relays in parallel, such as the durakool dg85 series. if driving relays a pull-down resistor is not required. when the switch is in the safe area (tilt angle is less than 40), the output is high and the relay is driven on. if the switch is tilted such that it detects an angle greater than 40 then the output goes low and the relay is turned off. if the switch is unpowered, the output is off. once the switch has detected an over angle, there is a 3 second (optional 1 s) delay and the output goes low and stays low, even if the power to the switch is removed and re-applied. if the reset option is specifed, the switch can be reset using a separate con - fgurator module. the optional led illuminates if the switch has detected an over angle and the output is low. the led will turn off if power to the switch is removed, but will turn on again when power is re-applied (until reset for resettable versions). +


▲Up To Search▲   

 
Price & Availability of TD4PX

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X